120mmx3core Xlpe 11kv Bicc Electric Cable

85,000.00

Description

About the Product 🔑

Cable Icon Electric XLPE Power Cable 11kV PILC Cu 3 Core 120mm2 Armoured Medium Power Cable
Power Plug Icon PVC and XLPE insulated armoured cables with FR, FRLHCL bedding and sheath will pass the test requirements under category C of IEC 60332 Part 3 specification for “test on electrical cables under fire condition on bunched wires or cables”.
Copper Icon 11KVXLPE3X120RD 11kV power cable, 3 core, 120mm² stranded plain annealed circular compacted copper conductors, XLPE easy strip insulation, copper tape screen, PVC bedding, galvanised steel wire armour, Red PVC sheath. BS6622, IEC 60502, flame propagation to BS EN60332.
Product Image 1
Product Image 2
Product Image 3

Key Features 🔑

Power Cable Icon Medium Voltage Cable Design
Test Tube Icon Medium Voltage Cable Test
Electrical Parameters Icon Electrical Parameters
De-rating Icon De-rating Factors
Short Circuit Icon Short Circuit Currents
Dimensions Icon Dimension Data of XLPE Cables 3.6/6 (7.2) kV – Single Core Cable
Multi-window Icon 3.6/6 (7.2) kV – Multi Core – Unarmored
Multi-window Icon 3.6/6 (7.2) kV – Multi …
Shield Check Icon 11KV LSZH 3 CORE COPPER SCREENED CABLE APPLICATION
Installation Icon Suitable for installation in power networks, underground and in cable ducting.
Fire Extinguisher Icon Low smoke zero halogen sheath makes it suitable for installations where fire, smoke emissions and toxic fumes create a potential threat.
Partial Discharge Icon Electrical stress in the fillers around the cores produced partial discharge activity which impinged on the surface of the XLPE insulation, steadily eroding the dielectric and resulting in premature cable failure.
Screen Full Icon For most normal applications, therefore, polymeric cables rated at 3.8/6.6kV and above have screened cores.
Heavy Duty Icon Mainly use for heavy duties installation and also provide high quality voltage

Usage Instruction 🛠️

Step 1: ⚙️ Understand Medium Voltage Cable Design.

Step 2: 🧪 Perform Medium Voltage Cable Test.

Step 3: ⚡ Check Electrical Parameters.

Step 4: 📉 Consider De-rating Factors.

Step 5: 💥 Analyze Short Circuit Currents.

Step 6: 📏 Refer to Dimension Data of XLPE Cables 3.6/6 (7.2) kV – Single Core Cable.

Step 7: 🔌 Install 3.6/6 (7.2) kV – Multi Core – Unarmored cables.

Step 8: 🎚️ Use 3.6/6 (7.2) kV – Multi … cables.

Step 9: 🏠 Install 11KV LSZH 3 CORE COPPER SCREENED CABLE APPLICATION in power networks, underground and in cable ducting.

Step 10: 🔥 Use in installations where fire, smoke emissions and toxic fumes create a potential threat due to low smoke zero halogen sheath.

Step 11: 💡 Avoid electrical stress in fillers around cores to prevent partial discharge activity and premature cable failure.

Step 12: 🛡️ Utilize screened cores for polymeric cables rated at 3.8/6.6kV and above for most normal applications.

Step 13: 💪 Use for heavy duties installation and to provide high quality voltage.

Product Specification 📱

Specification Description
Voltage Icon 11kV
Cable Icon XLPE PILC Cu 3 Core
Wire Icon 120mm²
Armored Icon Armoured
Fire Protection Icon FR, FRLHCL bedding and sheath
Standard Icon IEC 60332 Part 3 Category C
Copper Wire Icon Stranded plain annealed circular compacted copper conductors
Insulation Icon XLPE easy strip insulation
Tape Measure Icon Copper tape screen
Bed Icon PVC bedding
Steel Icon Galvanised steel wire armour
Red Circle Icon Red PVC sheath
Standards Icon BS6622, IEC 60502, BS EN60332

Product Details 🏷️

BICC CABLES Background General Technical Information Introduction Medium Voltage Cable Design Medium Voltage Cable Test General Information Cables Electrical Parameters De-rating Factors Short Circuit Currents Dimension Data of XLPE Cables 3.6/6 (7.2) kV – Single Core Cable 3.6/6 (7.2) kV – Multi Core – Unarmored 3.6/6 (7.2) kV – Multi …

BS7835 11KV LSZH 3 CORE COPPER SCREENED CABLE APPLICATION The 11KV Medium Voltage British Standard cable is suitable for installation in power networks, underground and in cable ducting. Its low smoke zero halogen sheath makes it suitable for installations where fire, smoke emissions and toxic fumes create a potential threat.

That is, the electrical stress in the fillers around the cores produced partial discharge activity which impinged on the surface of the XLPE insulation, steadily eroding the dielectric and resulting in premature cable failure. For most normal applications, therefore, polymeric cables rated at 3.8/6.6kV and above have screened cores.

Reviews

There are no reviews yet.

Be the first to review “120mmx3core Xlpe 11kv Bicc Electric Cable”

Delivery & Returns