### About the Product 🔑

The B1B series circuit breakers, which comply with UL489 standard appendix SC, can be used for overcurrent protection of the main circuit. The maximum voltage of the B1B series is DC 1000V, and it has a high breaking capacity of 10kA, making it the preferred product in the battery power industry.

The KRF 2 Pole MCB DC Circuit Breakers offer reliable protection and performance for DC systems, ensuring safety and efficiency in various applications. High Voltage & Current Capacity Designed to handle a rated operating voltage up to DC1000V and current up to 63A. Ideal for isolation, overload, and short circuit protection. Suitable for photovoltaic, industrial, and …

The first DC isolator fully compliant with AS 60947.3:2018 DC-PV2 In Australia and New Zealand DC isolating switches must have a valid Certificate of Conformity confirming the product complies with AS 60947.3:2018 DC-PV2. And a breathing valve is attached on the DC isolator. BYH-32 solar DC isolator up to is designed according to IEC60947-3 / AS60947.3:2018 -PV2 standard. The first …

Product Image 1
Product Image 2
Product Image 3

### Key Features 🔑

  • B1B series circuit breakers comply with UL489 standard appendix SC.
  • Used for overcurrent protection of the main circuit.
  • Maximum voltage of the B1B series is DC 1000V.
  • High breaking capacity of 10kA.
  • Preferred product in the battery power industry.
  • KRF 2 Pole MCB DC Circuit Breakers offer reliable protection and performance for DC systems.
  • Ensuring safety and efficiency in various applications.
  • High Voltage & Current Capacity.
  • Designed to handle a rated operating voltage up to DC1000V.
  • Designed to handle current up to 63A.
  • Ideal for isolation, overload, and short circuit protection.
  • Suitable for photovoltaic, industrial, and …
  • First DC isolator fully compliant with AS 60947.3:2018 DC-PV2 In Australia and New Zealand.
  • DC isolating switches must have a valid Certificate of Conformity confirming compliance with AS 60947.3:2018 DC-PV2.
  • A breathing valve is attached on the DC isolator.
  • BYH-32 solar DC isolator is designed according to IEC60947-3 / AS60947.3:2018 -PV2 standard.
  • Thermo-magnetic circuit breaker with positive contact indication for control, protection and isolation of electrical supplied with direct current.
  • MCB is suitable for photovoltaic applications.

### Usage Instruction 🛠️

  • Step 1: 🔌 Connect the circuit breaker for overcurrent protection of the main circuit.
  • Step 2: 💡 Ensure the circuit breaker has a rated voltage up to DC 1000V.
  • Step 3: ⚙️ Utilize the high breaking capacity of 10kA for the battery power industry.
  • Step 4: ⚡ Apply the KRF 2 Pole MCB DC Circuit Breakers for reliable protection and performance in DC systems.
  • Step 5: 🔌 Use for isolation, overload, and short circuit protection.
  • Step 6: ⚠️ Ensure compliance with AS 60947.3:2018 DC-PV2 for DC isolating switches.
  • Step 7: ⚙️ Install the BYH-32 solar DC isolator according to IEC60947-3 / AS60947.3:2018 -PV2 standard.
  • Step 8: 💡 Use the thermo-magnetic circuit breaker with positive contact indication for control, protection and isolation of electrical supplied with direct current.
  • Step 9: ☀️ This MCB is suitable for photovoltaic applications.
  • Step 10: ⚡ The DZ47Z DC miniature circuit breaker is mainly used in circuits with rated voltage not exceeding 500V/1000V (optional) DC and rated current 6A~63A.
  • Step 11: 🛡️ This series of circuit breakers can provide short-circuit and overload protection, and can also be used for control and isolation.
  • Step 12: ⚡ C.BREAKER TMAX T4V 250 1150V AC-1000V DC FIXED FOUR-POLE WITH FRONT TERMINALS FOR CABLE Cu AND THERMOMAGNETIC RELEASE TMD R 32-320 A.

### Product Specification 📱

Specification Description
Series B1B ⚡
Standard Compliance UL489 Appendix SC 📜
Application Overcurrent Protection 🔌
Maximum Voltage DC 1000V ⚡
Breaking Capacity 10kA 💥
Industry Battery Power 🔋
Pole 2 Pole ✌️
Rated Operating Voltage Up to DC1000V ⚡
Rated Current Up to 63A 📏
Protection Isolation, Overload, Short Circuit 🛡️
Suitable For Photovoltaic, Industrial ☀️🏭
Isolator Standard AS 60947.3:2018 DC-PV2 ✅
Model BYH-32 📈
Circuit Breaker Type Thermo-magnetic 🔥
Contact Indication Positive 👍

### Product Details 🏷️

This section contains additional information about the product.

Details Information
Application DZ47Z DC miniature circuit breaker is mainly used in circuits with rated voltage not exceeding 500V/1000V (optional) DC and rated current 6A~63A. This series of circuit breakers can provide short-circuit and overload protection, and can also be used for control and isolation.
Model C.BREAKER TMAX T4V 250
Voltage Rating 1150V AC-1000V DC
Configuration Fixed Four-Pole with Front Terminals for Cable Cu
Release Type Thermomagnetic Release TMD R 32-320 A
Use Thermo-magnetic circuit breaker with positive contact indication for control, protection and isolation of electrical supplied with direct current. Suitable for photovoltaic applications.

Full Images

Product Standout Benefits

Protect your power distribution facilities from overload and short-circuit damage with this versatile circuit breaker. It’s designed for control and isolation, ensuring your circuits and electrical appliances are safeguarded in a timely manner. 🔥

  • Fast Trip Protection: Featuring an electromagnetic trip system, this circuit breaker trips immediately upon detecting a short circuit, ensuring the safety of your circuit.
  • Assisted Arc Extinguishing: Designed to tackle the challenges of DC arc extinguishing, this mini circuit breaker incorporates a magnetic system to aid in arc suppression.
  • Easy Installation: With a modular structure and a bistable locking clip, it can be effortlessly installed onto the DIN standard guide rail in your distribution box.
  • Wide Application: Perfect for DC power systems, ship electric power systems, solar photovoltaic systems, and other DC applications. It’s widely used in automobiles, yachts, car audio, amplifiers, and trucks.

Customer Questions and Answers

Q: How do I use this product?

A: Just install this circuit breaker on your DIN standard guide rail in the distribution box following its modular structure, and it’s ready to protect your circuits!

Q: Is it good for protecting my car’s audio system?

A: Absolutely! It’s widely used in car audio and amplifier protection, so it’s perfect for keeping your system safe.

Q: How do I take care of it?

A: This circuit breaker is designed for reliable protection. Ensure it’s installed correctly in a suitable DC system application.

Q: Can I use this with a 1000V DC system?

A: Yes, it is suitable for DC power systems with rated DC voltage of 1000V and below.

Q: What type of tripping characteristic does it have?

A: This circuit breaker features a C type instantaneous trip characteristic.

Q: How many poles does it have?

A: It is a 2-pole circuit breaker.

Buyer’s Guide

Ready to get your circuit breaker set up? Here’s a quick and easy guide to make sure you’re all set!

  • Step 1: 📦 Review the Details
    Check out the item type, trip characteristics, and pole count to make sure it’s exactly what you need for your DC system.
  • Step 2: 📝 Read the FAQs
    Go through the FAQs for quick answers to common questions about its application and specifications.
  • Step 3: 🛒 Add to Cart & Checkout
    Once you’re confident, add the circuit breaker to your cart and proceed with the checkout.
  • Step 4: 📦 Upon Delivery
    When your circuit breaker arrives, check that you received the correct item and that the manual is included.
  • Step 5: 🛠️ Consider Related Products
    Ensure you have the necessary components for installation on a DIN standard guide rail in your distribution box.

Reviews

There are no reviews yet.

Be the first to review “32 Amp 1000 Volt DC Circuit Breaker New Condition”

Delivery & Returns